• Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17
  • Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17
  • Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17
  • Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17
  • Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17
  • Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17

Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17

Portable: Non Portable
Form: Flatbed
Application: Security Check, Industrial
Type: Industrial High-definition X-ray Detector
Certification: CE, ISO
Customized: Non-Customized
Diamond Member Since 2013

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
MSLMX17
Warranty
1 Years
Focus Range
0.6mm/1.0mm
Standard Output Power: 40kw
5.0kw
Hard Disk
500 GB
Properties
Medical X-ray Equipments & Accessories
After-Sale Service
Online Technical Support
Rotary Anode
10000 Rpm
Ma Range
1.0MMA (75kv)
Transport Package
Carton
Specification
0
Trademark
MSL
Origin
Guangdong China
Production Capacity
5000 Piece/Pieces Per Month

Product Description

Good Quality X-Ray Radiography Machine X-Ray Flaw Machine MSLMX17
Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17

Product Description

Good Quality X-Ray Radiography Machine X-Ray Flaw Machine MSLMX17mobile x ray machine digital dr system for hospital
 

THA MECHANICAL PART

The mechanical parts of this series machine consist of the following major components: the base unit, pillar parts (including Upright Post pieces, Rocker Arm pieces, Locking pieces), tube parts, etc.

1. Base unit

The instrument adopts Orientation foot brake, one of most advanced structures, which is stable and it is not easy to break. During its usages, the machine can be fixed quickly with the brake structure, preventing the machine from moving forward and backward. It is convenient to take radiography in a stable and accurate situation. Note: If some faults happen, please follow as bellow:
1) It brakes effectively during the movement, but when users release the foot brake, the instrument cannot move normally. At this moment, please move the machine forward and backward slowly and brakes will be able to return to its original position, then you can push the machine easily.
2) After release the foot brake and proceed as the step 1), if the machine still can not move, please use some soft object to beat the brake block below the base unit until it can work properly. Usually it is the reason that it works for a long time, and the base of the brakes lacks lubricant. Please move the arm to the lowest position and lock until hearing a "crack" locking sound, and then gently move up a little and stop when meet resistance, then move the machine to another side. The users can see the brake system below the base unit and add oli, to make it slide freely. After that, it will work well.

3) During the movement the machine in the collision process, the caster is damaged. Please tilt the machine as the above two methods, raise the damaged side of the wheel, and remove it. Then repair or replace it.


2. Pillar parts

This machine is applied to a combined pillar and rocker arm. It can take films in every position the tube parts stop, by using the built-in tension spring and rocker arm to realize the up and down movement of tube parts. Note: If some faults happen, please follow as bellow:
1) Tube components cannot stop at a certain location as the user need.
It is caused by the long time usage of tension spring. Please tilt the machine according to the "base unit" in Step 2, then use the wrench to adjust the extension spring bolt of the base unit, rotate clockwise to increase the  tension, until it reaches a balance position.
2) Locking pieces cannot work.
Check whether the head pins of both sides on chrome-plated handles is broken or not. If yes, please adjust the tension spring according to above NO.1), counter-clockwise rotate until the tension spring effect can not afford to pull up, and remove the tube parts , then remove the locking pieces to check the cushion of both sides loose or not. Pleasure repair the cushion, then install locking pieces into the arm pieces together, then install the tube parts, at last adjust the tension spring bolt until balance.


3. Tube parts

Tube parts is composed of beam collimator, rotating handle, cover and tube pieces. If some faults happen during use, such as not lighting of beam collimator lamp etc., please repair and maintain according to the corresponding sections of the manual; if there is something wrong with the tube pieces, please contact our company.

Product Parameters


Main Technical Parameters:
 
Specifications
 Power Output:    5.0KW
 Frequency :       50KHz

 X-ray Tube :      Fixed anode
 Focus :    1.5
Tube Voltage :     40~120KV   (interval 1KV)
Tube Current :     40~49KV        100mA    1~180 mAs
                              50~59KV        77mA      1~140 mAs
                              60~69KV        64mA      1~125 mAs
                              70~79KV        55mA      1~110 mAs
                               80~89KV        49mA      1~100 mAs
                                 90~99KV        44mA      1~80 mAs
                               100~109KV   32mA       1~63 mAs

               110~120KV   25mA       1~50 mAs
mAs        :    1.0~180 mAs (46 steps)
Power Supply:     220V±10%  50Hz   inner-resistance≤1.0Ω
Operation Method:   Wire/Wireless control , 20 meters microwave remote control exposure. (Advantage) . It is different from infrared remote control exposure, does not suffer any obstacles in the way

 

Packing Details :  1220mm×900mm×1460mm  ,   1.7CBM  
                                            N.W. 142kgs      G.W.212kgs



Parameters :

General-purpose, mobile  X-ray system, dedicated for radiography of standing, seated or recumbent patients as well as for patients in bed or on the operating table and as a standby emergency unit. High-frequency X-ray generator with the following output:
1. Generator output: 5.0 kW
2. kV range:  40 kV - 120 kV in 1kv steps 
3. mA range:    25~100 mA
4. Exposure time: 4 films per min, less than 20 ms per film
5. X-ray tube:
Stationary anode tube with a focal spot of 1.5*1.5 mm 
6. Collimator:
bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
7.Power requirements :Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
8.Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
9.The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional ,different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.
10.The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs
The unit include, power plugs that are sufficient for the maximum voltage and current of the unit. 
11. The maximum distance from the ground: ≥ 17500mm, and minimum distance from the ground :≤500mm, rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, The collimator can rotate 180 °


Standard Configuration:

1 ,Modular high-frequency and high-voltage X-ray generator; High-frequency inverter power.(5.0KW, 120KV, 100mA, 40KHZ)                                   one set
2,Innovative mobile X-ray photography Main frame                        one set
3,Mobile X-ray photography control system                               one set
4,Symmetric Adjustable beam limiter with light                            one set
5,Remote controller  ( Hand hold  controller  and Wireless Microwave control ,the distance is 20 meters )  one set
6,General spare parts                                            Several


Usage:

This is a modular X-ray photography medical diagnosis equipment, which is available for wards,emergency,operating room,ICU and so on. An mobile diagnosis equipment for photography of body locutions such as head,arms,thoracic cavity and waist abdomen.

Features:

Lovely appearance, and easy to move and operate; Possess all the features of all the mobile X-ray photography machines.
Rocker arm apply the patent technology of single-arm support and self-balanced. This technology makes the appearance and operation much more beautiful and convenient.
 Apply the design of expansion gate design, the machine will automatically locked when hand-off which makes the movement much safer.
 Apply the patent technology of auto-trim patent between arm rotation and battery box. The machine can automatically adjust the barycentre according to the rotation angle of the arm. All this make the series the lightest and smallest and easy for movement among like products.

We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low , to protect the patient better.
Adopt the technology of kV and mAs numeral closed loop control, Real-time control of the microprocessor, which ensure the accuracy and repeatability of the output dose.
The parameter can be adjust by the KV and mAs two-button system. High- brightness,blue screen LCD display. With multiple security protect function such as over-voltage, over-current.
With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.
With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.
Has a set of failure cascading failure function. Display the failure code. The system will automatically reset when the power is off which ensure the information safe.
With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.

With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures.
The arms can rotate ±90°left and right. It is convenient to poisoning.
Adopt manual control and remote control methods to control the photography function





 

Detailed Photos

 

Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17

 

Company Profile

Good Quality X-ray Radiography Machine X-ray Flaw Machine Mslmx17

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now