20kw 32kw 50kw High Frequency X-ray Machine
Medical Radiography Diagnostic Floor-mounted Digital Radiography
MSLHX04
Product Description
This high frequency X-ray machine belongs to class I type B equipment, use widely in the medical treatment unit for diagnostic X-ray radiography. Maximum power output is 20 kW, tube current adjusting range is 16 mA ~ 200 mA, tube voltage regulating range is 40 kV ~ 125 kV, the current product range is 0.5 mAs ~ 320 mAs.
This product has the following outstanding characteristics:
a) Analog and digital double loop with high-precision control mode
b) High precision of radiography time control
c) High precision tube current control
d) A variety of radiography setting modes, fast human body radiography program, simplify the operation.
e) Self-protection, fault self-diagnosis
f) Small volume, light weight, reduce installation space
This product composes of the following sections, show in figure
a) High frequency high voltage x-ray generator (including console)
b) X-ray tube component
c) High voltage cable
d) Radiography bed (including X-ray chest frame, collimator,etc.).
Product Parameters
Parameter |
20kw 200mA |
32kw 400mA |
50kw 630mA |
Intermittent mode |
100kV ,200mA,20kW |
100kV ,400mA, 32kW |
100kV ,630mA, 50kW |
Power Voltage |
Three-phase five wires 380V+38V |
Tube Current |
Radiography16mA~ 200mA |
Radiography16mA~ 400mA |
Radiography16mA~630mA |
Output Voltage |
Radiography 40-125KVstep 1kV |
Resistance Power |
less than 0.59 |
Output power |
20kW |
32kW |
50kW |
Exposure Time |
Radiography 0.0025s~ 6.4s adjustable |
Nominal Frequency |
230kHz |
Anode speed |
2800r/min |
Anode heat capacity |
140KHU |
Focus Small focus |
1.0mm |
Large focus |
2.0mm |
L*W*H of bed surface |
2100mmx825mmx650mm |
Horizontal moving range |
2250mm |
Vertical moving range |
2825 mm |
Grid Ratio |
10:01 |
Grid Density |
240 lines/cm |
Focus Distance |
100cm |
Cassette size |
5"x7" 8"x10" 10"x12" 11"x14" 14" x17" |
Transportation and storage conditions:
*Ambient temperature: -200C~+700C
*Relative humidity:10%~1-100%(including condensation)
*Atmospheric pressure:50Kpa~106Kpa
Main technical parameters
*Function:radiography
*X-ray machine maximum output power Intermittent mode 100Kv,200ma,20kw
*Adjusting range of x-ray machine tube current and tube voltage
Range of x-ray tube current:16ma~200ma
Rang of x-ray tube voltage:40kv~125kv
*Exposure time:0.0025s~6.4s
*Nominal working frequency>=30khz
*Power supply:three-phase five wires 380v + -38v
Main configuration
*High frequency high voltage generator (including control console)
*X-ray tube
-Focus:small focus:1.0mm,large focus:2.0mm
-Anode thermal capacity:140khu
-Collimator power supply:ac24v
*Radiography bed
-Single phase 220v + -22v,50Hz + -1Hz
-X-ray components supporting frame
Braking mode:elecrtomagnetic brake,
braking force>=98N,
buttor operation filter:N40,r10,11,stationary type,size:14"*17"
-Bed size:L2000mm*w760+H685mm
Vertical moving range: >=825
Horizontal moving range:>=250mm