The high frequency high-voltage x-ray generator for medical diagnosis belongs to type I of medical instrument equipment, which is widely used in productive establishment for producing high frequency x-ray machine for medical diagnosis as the supporting of high frequency x-ray machine core components for medical diagnosis and upgrade the technology of the high frequency x-ray machine for medical diagnosis. The maximumpower output is 50kW, the adjusting range of radiography tube current is 10mA ~ 630mA, the adjusting range of radiography tube voltage is 40 kV ~ 150 kV, the range of current-time product is 0.5mAs ~ 630mAs, and working frequency ≥ 100 kHz.
The product has the following prominent features:
Simulation and digital double loop accuracy control method:
With high frequency inverter circuit and microprocessor, simulation make up of the special chip PWM, digital double
loop feedback control method, to achieve high accuracy high voltage output, even if power fluctuation, still can output stable x-rays;
High precision radiography time control:
The shortest exposure time is 0.002 seconds, can make radiography fast at any time and completely free the influence of power phase, and produce high quality x-ray images easily and reduce patients suffering x-ray radiation at the same time.
High precision tube current control:
x-ray tube current is adopted two grades high frequency converter, sampling tube current of high speed A/D converter through microprocessor calculation for the real-time control, microprocessor manage the allowing load of x-ray tube, x-ray tube efficiently capable radiography conditions can be set.
Kinds of setting modes for radiography conditions:
Choose kV, mA and mAs respectively for radiography conditions set, the quick anatomy programming radiography (APR) for human body is simplified for the operation; According to x-ray tube capacity limit locking three parameters select and make capacity protection;
Default self-protection, self-diagnosis:
Once appear malfunction, generator chain protection, alarm device, inquiring fault code, convenient for maintenance treatment;
Small size, light weight, reducing installation space.
Working condition:
Environmental temperature: +10ºC ~ +40ºC
Relative humidity: 30% ~ 75%
Atmospheric pressure: 70kpa ~ 106kpa
Transportation and storage condition:
Environmental temperature: -20ºC~+70ºC
Relative humidity: 10% ~ 100% (including condensing)
Atmospheric pressure: 50Kpa ~ 106Kpa
Power requirement:
Power voltage: AC380V ± 38 V
Phase number: Three phase five wires
Power frequency: 60Hz±1Hz
Power inner resistance: less than 0.5 Ω
Working system: Intermittent load and continuous run
Input power: ≤ 80kVA
Maximum output power:
P= 100kV×500mA = 50kW
Nominal power:
100kV, 500mA, 0.1s, 50kW
Adjusting range of tube voltage and current:
Radiography tube voltage: 40 kV ~ 150 kV;
Radiography tube current: 10mA ~ 630mA
The deviation of x-ray tube voltage: ±10%
The deviation of x-ray tube current: ±20%
Notice: Current and current-time product arrange are according to R' 10 number system.
Operations Console:
Microprocessor controlled Digital display, LCD touch screen
Line voltage adjustment 180-260V
Overload protection system
Emergency switch
Circuit breaker main switch
High voltage generator (including computer console):
50KW/150kVp energy storage type high frequency
Input power: 380V, 60Hz ± 1Hz.
Power internal resistance: < 0.5Ω
Output power: 50kW output voltage: 40 ~ 150kV output current: 10~630mA
nominal frequency ≥ 100kHz high voltage generator
Time range: 0.0025-6.3s
X-ray Tube:
Dual Focus:
small 0.6mm/1.2mm,
With 300KHU Heat Unit capacity for rotating anode
150kVp, High/standard speed rotor
X-ray Tube:
Dual Focus: small 0.6mm/ large1.2mm,
With 300KHU Heat Unit capacity for rotating anode
Table:
Stationary
Radiographic Enclosed Style Table;
Wall mounted
Bucky Grid, Ratio: 12:1
Total filtration 2.5mm Al equivalent
Inherent filtration 1.5mm Al equivalent
Accessories:
1pc film viewer, 4 banks, 14"x17" each bank
1set x-ray film markers composed of English numbers and alphabets
2pcs lead apron with 0.25mm lead equivalence
2pcs thyroid shield, 0.25mm lead
4pcs 14"x17" Green sensitive cassettes
4pcs 11"x14" Green sensitive cassettes
4pcs 8"x10" Green sensitive cassettes
Anode cooling chart
Tube rating chart