Power requirements |
Voltage | AC380V/400V±10% | |
Frequency | 50Hz | ||
Resistance | ≤0.1Ω | ||
Capacity | ≥63kVA | ||
Mechanical parameter |
Column vertical movement distance | 1160mm (Error: ±5%) | |
Column lateral movement distance | 1730mm (Error: ±5%) | ||
Chest film frame lifting distance | ≥1200mm | ||
Tube assembly rotation angle | -90°~+90°, manual rotation | ||
Column rotation angle | -180°~+180°, manual rotation | ||
Patient table X-axis movement distance | 900mm (Error: ±5%) | ||
Patient table Y-axis movement distance | 260mm (Error: ±5%) | ||
Patient table dimensions (L×W×H) | 2110mm×822mm×656mm (Error: ±5%) | ||
Max. Patient Weight (kg) | 150kg | ||
Effective filtration of photographic table | 0.2 mmAl | ||
High voltage generator |
Input power voltage | AC 380V/400V±10% | |
Frequency | 50Hz | ||
Output nominal electric power | 50kW (500mA,100kV,0.1s) | ||
Tube voltage/kV | 40kV~150kV, digital button adjustment, minimum adjustment step length is 1kV; | ||
Tube current/mA | 10mA~630mA, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button; | ||
Loading time | 1ms~6300ms, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button; AEC nominal shortest irradiation time: 1.6ms | ||
Current time product/mAs | 0.1mAs~630mAs, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button; | ||
Exposure technology | kV-mA-ms, kV-mAs | ||
Loading conditions at Max. mA | 79kV,630mA | ||
Loading conditions at Max. kV | 150kV,320mA | ||
X-ray tube |
Anode input power | Large focal spot: 50kW; Intermediate focal spot: 20kW |
|
Focal spot | 0.6/1.2mm | ||
Anode speed | 2700RPM (r/min) | ||
Nominal tube voltage | 150kV | ||
Anode heat content | 163kJ (230kHU) | ||
Radiation spectrum characteristic of target material | See appendix 10.4 | ||
Heat capacity of X-ray tube assembly | 900kJ (1250kHU) | ||
Target angle | 12° | ||
Inherent filtration | 1.3mm Al/75kV | ||
Envelope voltage | See appendix 10.4 | ||
Envelope current | See appendix 10.4 | ||
Weight | 16kg | ||
Beam limiting device |
Inherent filtration | 1.5 mm Al | |
Max. tube voltage | 150kV | ||
Mean exposure intensity | >100Lux, SID100cm | ||
Light field switch | Manual | ||
Exposure time | 30s±5s | ||
Input power | DC24V±2.4V,10VA | ||
Min. irradiation field | <30mm×30mm at SID 100cm | ||
Max. irradiation field | 430mm×430mm at SID 100cm | ||
Light field deviation | ≤2% | ||
Anti-scatter Grid |
Grid 1: Ratio 8:1; grid density: 230lp/cm; focal distance:130cm | ||
Grid 2: Ratio 10:1; grid density: 230lp/cm; focal distance:100cm | |||
Detector CareView1500L |
Dimensions | 35cm×43cm | |
Effective number of bits | ≥14bit |